Error Code List Chapter4. Cash & Check In Module
4-46
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I2315
[Shutter]Fault of calling a
undefined command from Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2318
[Shutter]Fault of performing a
undefined process flow from
Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2319
[Shutter]BDS06 Dark Timeout
when performing low-speed
moving path down
1. Execute CCIM initialization.
2. Check whether the sensor (BDS06)
detecting the Bundle low-speed moving
media is polluted when the same error
occurs after initialization.
I234A
[Shutter]Bundle Sub action
Timeout
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I2360
[Shutter]SCM and BC Part
residual fault.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I23D2
[Shutter] Ultrasonic sensor does
not operate.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
3. Check whether the SCM internal
ultrasonic sensor (FDS06) is polluted
when the same error occurs after
rebooting.
I23D3
[Shutter]BC Task Timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I23F0
[Shutter]Bundle Task Skip.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I23FF
[Shutter]Bundle Task force shut
down.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2801
[Shutter] A command was not
executed due to a fault which has
occurred while preparing the main
task.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2802
[Shutter]Main Task force shut
down.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2803
[Shutter] Receives a command
which has not been defined in the
main task.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2804
[Shutter]Internal Error while the
main task is operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2805
[Shutter]Bundle part operation
timeout
1. Remove the residual media at the
Bundle part (1).
2. Execute initialization.