Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-21
Code
Problem Description
Troubleshooting
517G700
Detect the rear end in the tape
during Deposit Ready.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Cheeck whether black tape is wrap
with a drum in the TE(12)
4. Remove notes remain in the TE
517J100
TE drum full during Deposit
Ready.
1. Open the upper unit
2. Check the notes remain in the TE(12)
3. Remove notes remain in the TE
517R100
TE message timeout error
during operation ready in
theDeposit Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
517R200
TE message timeout error
during transaction operation in
the Deposit Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
517R300
TE message timeout error
during postprocessing of
Deposit Ready Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
517RJ00
TE message timeout error
during Deposit Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
518HA01
Error GS801A during Deposit
Ready.
1. Check GS801A
2. Operate to initialize BRM(Recovery)
518HA02
Error GS801B during Deposit
Ready.
1. Check GS801B
2. Operate to initialize BRM(Recovery)
518HA03
Error GS801A, GS801B during
Deposit Ready.
1. Check GS801A, GS801B
2. Operate to initialize BRM(Recovery)
518HA04
Error GS802A during Deposit
Ready.
1. Check GS802A
2. Operate to initialize BRM(Recovery)
518HA05
Error GS801A, GS802A during
Deposit Ready.
1. Check GS801A, GS802A
2. Operate to initialize BRM(Recovery)
518HA06
Error GS801B, GS802A during
Deposit Ready.
1. Check GS801B, GS802A
2. Operate to initialize BRM(Recovery)
518HA07
Error GS801A, GS801B,
GS802A during Deposit
Ready.
1. Check GS801A, GS801B, GS802A
2. Operate to initialize BRM(Recovery)
518HA08
Error GS802B during Deposit
Ready.
1. Check GS802B
2. Operate to initialize BRM(Recovery)
518HA09
Error GS801A, GS802B during
Deposit Ready.
1. Check GS801A, GS802B
2. Operate to initialize BRM(Recovery)
518HA10
Error GS801B, GS802B during
Deposit Ready.
1. Check GS801B, GS802B
2. Operate to initialize BRM(Recovery)
518HA11
Error GS801A, GS801B,
GS802B during Deposit
Ready.
1. Check GS801A, GS801B, GS802B
2. Operate to initialize BRM(Recovery)
518HA12
Error GS802A, GS802B
during Deposit Ready.
1. Check GS802A, GS802B
2. Operate to initialize BRM(Recovery)
518HA13
Error GS801A, GS802A,
GS802B during Deposit
Ready.
1. Check GS801A, GS802A, GS802B
2. Operate to initialize BRM(Recovery)