Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-469
Code
Problem Description
Troubleshooting
5K4GB00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
5K4GC00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
5K4GG00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5K4GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5K4J300
Failure to RC4 full check
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
5K4R100
RC4 message timeout error
during operation ready in the
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K4R200
RC4 message timeout error
during transation operation in
the Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K4R300
RC4 message timeout error
during postprocessing of
Withdrawal Reject Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K4S100
Undefined return value of RC4
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K4S200
Undefined command of RC4
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)