Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-393
Code
Problem Description
Troubleshooting
5D1J300
RC1 full check failure during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
5D1R100
RC1 message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D1R200
RC1 message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D1R300
RC1 message timeout error
during postprocessing to
Initialize error .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D1S100
Undefined return value of RC1
during Initialize.
1. Operate to initialize BRM(Recovery)
5D1S200
Undefined command of RC1
during Initialize.
1. Operate to initialize BRM(Recovery)
5D20500
GS205 light jam during
Initialize .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(15)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5D21100
GS201 sensor jam during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D21200
GS202 sensor jam during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance