Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-461
Code
Problem Description
Troubleshooting
5K2GB00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5K2GC00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5K2GG00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5K2GH00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5K2J300
Failure to RC2 full check
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
5K2R100
RC2 message timeout error
during operation ready in the
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K2R200
RC2 message timeout error
during transation operation in
the Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K2R300
RC2 message timeout error
during postprocessing of
Withdrawal Reject Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K2S100
Undefined return value of RC2
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K2S200
Undefined command of RC2
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)