Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-536
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5VBR000
RBU response timeout during
System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VBR700
RBU response message
timeout error during System
Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VBS000
RBU communication timeout
error when System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VBS100
RBU connection sequence
error when System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VBS200
RBU connection MI error when
System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VSSE00
Sequence number duplicated
with Version read command.
1. Check the detail sequence number of
bulk sending command
5VUS100
USB sequence number
duplicate error when System
Info Read.
1. Restart over AP-SP
5VUS300
USB command data length
error when System Info Read.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5W1SZ00
Management mode is not
´ No use´ even
through setting up RC1
denomination count is 0 in the
Initial Info Set.
1. Check setting up denomination of
cassette
2. Operate to initialize BRM(Recovery)
5W2SZ00
Management mode is not
´ No use´ even
through setting up RC2
denomination count is 0 in the
Initial Info Set.
1. Check setting up denomination of
cassette
2. Operate to initialize BRM(Recovery)
5W3SZ00
Management mode is not
´ No use´ even
through setting up RC2 and
RC3 denomination count is 0
in the Initial Info Set.
1. Check setting up denomination of
cassette
2. Operate to initialize BRM(Recovery)
5W4SZ00
Management mode is not
´ No use´ even
through setting up RC4 and
RC2 denomination count is 0
in the Initial Info Set.
1. Check setting up denomination of
cassette
2. Operate to initialize BRM(Recovery)
5W5SZ00
Management mode is not
´ No use´ even
through setting up RC5 and
RC2 denomination count is 0
in the Initial Info Set.
1. Check setting up denomination of
cassette
2. Operate to initialize BRM(Recovery)
5W8HA01
Error GS801A during Initial
Info Set.
1. Check GS801A
2. Operate to initialize BRM(Recovery)
5W8HA02
Error GS801B during Initial
Info Set.
1. Check GS801B
2. Operate to initialize BRM(Recovery)