Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-11
Code
Problem Description
Troubleshooting
I130B
[Initialize] Billpress Reject position
startup fault.
1. Check the inside of the Bundle(1).
2. Remove the alien materials of the
Billpress.
3. If no alien material exists in the
Billpress, check and remove the alien
materials in the Bundle Bill Press part
(BDS15, BDS16) sensors.
4. If no alien material exists, check
whether the sensor is polluted
I130D
[Initialize]Bundle residual fault.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists, check
whether the sensor in the Bundle(1) is
polluted.
I130F
[Initialize] Sensor fault when
preparing for separation of media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle entry part (BDS01,
BDS02) sensors.
3. If no alien material exists, check
whether the sensor is polluted
I1312
[Initialize] Fault of receiving media
returned due to low-speed moving
path up.
1. Open the door at the Bundle side and
remove the residual media.
2. Check and remove the alien materials
in the Bundle low-speed wheel position
control (BDS14) sensor.
3. If no alien material exists, check
whether the sensor is polluted
4. Initialize the device.
I1315
[Initialize]Fault of calling a
undefined command from Bundle.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1318
[Initialize]Fault of performing a
undefined process flow from
Bundle.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1319
[Initialize]BDS06 Dark Timeout
when performing low-speed
moving path down
1. Execute CCIM initialization action.
2. Check whether the sensor (BDS06)
detecting the Bundle low-speed moving
path media is polluted when the same
error occurs after initialization.
I131E
[Initialize]BDS06 Dark fault after
initializing the Bundle
1. Execute CCIM initialization action.
2. Check whether the sensor (BDS06)
detecting the Bundle low-speed moving
path media is polluted when the same
error occurs after initialization.
I131F
[Initialize]BDS17 Dark fault after
initializing the Bundle.
1. Execute CCIM initialization action.
2. Check whether the Bundle DC Motor
Encoder (BDS17) sensor is polluted
when the same error occurs after
initialization.