Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-433
Code
Problem Description
Troubleshooting
5FAE100
Received operation command
without Initial Info Set during
Shutter Close.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5FAE200
Status on not operation
receiption command during
Shutter Close.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5FAE300
Received operation command
without System Info Read
during Shutter Close.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5FAE400
Shutter close transaction was
executed without Initializing
after power on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5FAE600
Error to received Shutter close
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAEE00
RBU RS485 communication
sequence disorder during
Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAEF00
RBU RS485 connection line
disorder during Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAH500
Error to
NVRAM(128denominations)
Read/ Write during Shutter
Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5FAR100
Message timeout error during
operation ready in the Shutter
Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAR200
Message timeout error during
transaction operation in the
Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAR300
Message timeout error during
postprocessing of Shutter
Close Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAR700
RBU response message
timeout error during Shutter
Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FUS100
USB sequence number
duplicate error when Shutter
Close.
1. Restart over AP-SP
5FUS300
USB command data length
error when Shutter Close.
1. Check USB connection
2. Operate to initialize BRM(Recovery)