Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-104
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
53AA900
Status of BMD removal before
the operation during Deposit
End.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
53AAA00
Status of BC open before the
operation during Deposit End.
1. Open the upper unit
2. Check the lock lever in the BC
53AAB00
Status of RC full before the
operation during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the GSx11 full detection
sensor of recycle cassettes(A~E)
4. Open the cassette door
5. Check the notes full in the cassette
53AAC00
Status of RJC full before the
operation during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
53AAD00
Status of UTC1 full before the
operation during Deposit
End.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
53AAE00
Status of UTC2 full before the
operation during Deposit
End.
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
53AAF00
Status of RC empty before the
operation during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
53AE100
Received operation command
without Initail Info Set during
Deposit End.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
53AE200
Status on not operation
receiption command during
Deposit End.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
53AE300
Received execute command
without Read System Info.
during Deposit End.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
53AE400
Deposit End transaction was
executed without Initializing
after power on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
53AE600
Error to received deposit end
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization