Code
Problem Description
Troubleshooting
5D1G200
Failure to move stack position
of RC1 PP during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5D1G400
Failure to upword moving of
PP during RC1 stack roller
retreat movement in the
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5D1G500
Failure of RC1 stack roller
retreat during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
5D1G600
Exceeds retry count limit of
detecting RC1 stack
roller´s falling back and
avoiding during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
5D1G700
Failure to move RC1 feed
roller to home position during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
5D1G800
Failure to RC1 push pressure
movement during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the upper side of the recycle
cassette
5D1GA00
RC1 solenoid echo disorder
error during Initialize .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette(A) and
reload
4. Replace the cassette when same
error occurs