Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-246
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
57BH500
RC5 EEPROM read error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BH600
RC1 EEPROM Write error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BH700
RC2 EEPROM Write error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BH800
RC3 EEPROM Write error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BH900
RC4 EEPROM Write error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BHA00
RC5 EEPROM Write error
during Withdrawal.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
57BHB00
RC1 EEPROM data verify
error during Withdrawal.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
57BHC00
RC2 EEPROM data verify
error during Withdrawal.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
57BHD00
RC3 EEPROM data verify
error during Withdrawal.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
57BHE00
RC4 EEPROM data verify
error during Withdrawal.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
57BHF00
RC5 EEPROM data verify
error during Withdrawal.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
57BHG00
No detect inter lock during RC
EEPROM R/W during
Withdrawal.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
57BS000
RBU communication timeout
error during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
57BS100
RBU connection sequence
error during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
57BS200
RBU connection MI error
during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization