Code
Problem Description
Troubleshooting
531GC00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
531GG00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
531GH00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
531J300
Failure to RC1 full check
during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
531R100
RC1 message timeout error
during operation ready in the
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
531R200
RC1 message timeout error
during transation operation in
the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
531R300
RC1 message timeout error
during postprocessing of
Deposit End Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
531S100
Undefined return value of RC1
during Deposit End.
1. Operate to initialize BRM(Recovery)
531S200
Undefined command of RC1
during Deposit End.
1. Operate to initialize BRM(Recovery)
5320500
GS205 Light Jam during
Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(15)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).