Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-38
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5207100
Error occurred by the notes
disorder on the GS801 during
Deposit Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207200
Error occurred by the notes
disorder on the GS002 during
Deposit Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207300
Error occurred by the notes
disorder on the GS003 during
Deposit Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207400
Error occurred by the notes
disorder on the GS004 during
Deposit Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove the cassette not received(9)
5. Remove notes and substance in the
Rear Transport Path(6)
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207500
Error occurred by the notes
disorder on the GS005 during
Deposit Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207600
Error occurred by the notes
disorder on the GS006 during
Deposit Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove the forge note cassette(9)
5. Remove notes and substance in the
Rear Transport Path(6)
6. Check whether the sensor is
contaminated or not if there are No
notes or substance