Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-231
Code
Problem Description
Troubleshooting
575R300
RC5 message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
575RJ00
RC5 message timeout error
during Stop Ready in the
Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
575S100
Undefined return value of RC5
during Withdrawal .
1. Operate to initialize BRM(Recovery)
575S200
Undefined command of RC5
during Withdrawal .
1. Operate to initialize BRM(Recovery)
575S300
An inoperable command,
Withdrawal Ready is issued to
RC5 during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
575SZ00
Failure to separate required
Notes in the RC5 while
withdrawal stops to sepatate 0
count(NO available RC
cassette to separate).
1. Check the remained count in the RC
5762100
Error of notes remaind in the
CSM during Withdrawal .
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5762400
Undefined command error of
CSM during Withdrawal .
1. Operate to initialize BRM(Recovery)
5762500
The status of notes remain in
the CSM changed status of no
notes in the CSM during
Withdrawal .
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
5762600
The status of no notes in the
CSM changed The status of
notes remain in the CSM
during Withdrawal .
1. Open the upper unit
2. Open the CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
576G100
Error of receiving notes and
position of notes during
Withdrawal .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
576G200
Error of BP stack position
movement during Withdrawal .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
576G300
Error of BP deposit position
movement during Withdrawal .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM