Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-162
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5615500
Error occurred by the
Transport Path on the GS105
during Withdrawal Ready.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5616500
Error occurred by the
ReturnTrnasport Path(GS105)
during Withdrawal Ready .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5617500
Error occurred by the notes
disorder on the GS105 during
Withdrawal Ready .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
561G100
Failure of return notes to RC1
during Withdrawal Ready.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
561G200
Failure to move stack position
of RC1 PP during Withdrawal
Ready.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem