Error Code List Chapter4. Cash & Check In Module
4-196
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I786C
[Deposit OK]Timeout occurs while
resetting in Bundle mode (CST2)
1. Remove the residual media in the
device.
2. Execute initialization.
I786D
[Deposit OK]Timeout of preparing
for CST1 store (Escrow->CST2)
1. Remove the residual media in the
device.
2. Execute initialization.
I786E
[Deposit OK]Timeout of preparing
for CST2 store (Escrow->CST2)
1. Remove the residual media in the
device.
2. Execute initialization.
I786F
[Deposit OK]Timeout of checking
residual media in Bundle occurs
during initialization
1. Remove the residual media in the
device.
2. Execute initialization.
I7870
[Deposit OK]Failed to rewind while
the Escrow is empty (logical
sensor is empty)
1. Remove the residual media at the
Escrow part (12).
2. Remove the media residual at the
Escrow (ESS01, ESS02, ESS03) and
the pollution.
3. If no alien material exists, check
whether the sensor is polluted.
4. Execute CCIM initialization.
I7871
[Deposit OK]Deposit reject
command is received when the
residual media are not detected at
the Reject part.
1. Remove the residual media in the
device.
2. Execute initialization.
I7872
[Deposit OK]Detects residual
media at the Reject part
1. Remove the residual media in the
device.
2. Execute initialization.
I7879
[Deposit OK]Fault occurs while the
BC part is preparing.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I787A
[Deposit OK]BC response timeout. 1. Check the cable connecting between
Main and BC (Connector CN37).
I787B
[Deposit OK]The number of notes
which have passed BC is not
consistent with that of Escrow and
Reject.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I787C
[Deposit OK]BC operation is not
completed.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I7890
[Deposit OK]The number of media
of which store command is
received is larger than the number
managed by the CCIM.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I7893
[Deposit OK]Failure to check the
last note at the termination of mid
transport path while retracting
those.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I78E0
[Deposit OK]Anomaly of check
information
1. Remove the residual media in the
device.
2. Execute initialization.
I78F1
[Deposit OK]Internal Error while
the main task is operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.