Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-253
Code
Problem Description
Troubleshooting
I9C02
[Retract]FDS02 Light
Timeout(88ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor and the Bundle.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I9C03
[Retract]FDS03 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I9C04
[Retract]FDS04 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I9C05
[Retract]FDS05 Light
Timeout(88ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor and the Bundle.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I9C06
[Retract]FDS03, 04 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I9C07
[Retract]BCS01 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.