Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-317
Code
Problem Description
Troubleshooting
5AA2500
Status of remaining notes on
the Return Path(GS005)
before the operation during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2600
Status of remaining notes on
the Return Path(GS006)
before the operation during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2A00
Status of remaining notes on
the Return Path(GS021)
before the operation during
Retract CSM.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2B00
Status of remaining notes on
the Return Path(GS022)
before the operation during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2G00
Status of remaining notes on
the Return Path(GS614)
before the operation during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2H00
Status of remaining notes on
the Return Path(GS618)
before the operation during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5AA2J00
Status of remaining notes on
the Return Path(GS619)
before the operation during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance