background image

All descriptions illustrations, and specifications in this brochure should be 
considered approximate and may relate to optional equipment or feature

Quick User Guide

MorphoAccess

®

SIGMA Lite Series

MorphoAccess® SIGMA Lite+

MorphoAccess® SIGMA Lite

Summary of Contents for MorphoAccess SIGMA Lite Series

Page 1: ...trations and specifications in this brochure should be considered approximate and may relate to optional equipment or feature Quick User Guide MorphoAccess SIGMA Lite Series MorphoAccess SIGMA Lite Mo...

Page 2: ...TED Table of Contents MorphoAccess SIGMA Lite Series Quick User Guide 2015_2000005700 V11 2 Color Step Content One Overview Two Wiring Three Communications Four ACP or SDAC Five Administration Six Sof...

Page 3: ...guration with a USB mass storage key Power consumption shall not exceed 200mA Optical biometrical sensor Status LED Optional 2 8 touchscreen LCD SIGMA Lite Embedded web server configuration enrolment...

Page 4: ...1 4 Electronic documentation is provided in Adobe Acrobat format PDF Adobe Acrobat Reader is available at http www adobe com Step one overview Product packaging checklist QTY ITEM 1 MorphoAccess SIGMA...

Page 5: ...party product The MorphoAccess terminal sends a message to the Access Controller to activate the Alarm as soon as a malicious activity such as tamper or pulling is detected To secure an access IDEMIA...

Page 6: ...he result of the check is successful user recognized a message is sent to the Central Access Controller for additional access rights check If the user is allowed to access to the protected zone the ce...

Page 7: ...ontactless card in front of the reader Both Identification and Authentication triggers are enabled Triggering events are selected by the remote application Biometric check if enabled The user s captur...

Page 8: ...s Avoid biometric sensor exposure to a blinking light Avoid direct exposure of the biometric sensor to sunlight or to UV lights Outdoor installations recommendations Outdoor devices shall not encounte...

Page 9: ...ower failure by a dedicated component during a least 24 hours at 25oC without external power supply RJ 45 Ethernet PoE 25 ETH TX Orange 1 27 ETH TX Orange White 2 29 ETH RX Green 3 31 ETH RX Green Whi...

Page 10: ...iant The terminal is a Class 0 15 4W PD Powered Device Step two wiring RJ 45 1 Power 12V Red 2 Power GND Black A battery backup or uninterrupted power supply UPS with built in surge protection is reco...

Page 11: ...ack Red RS 232 from the Com Port RS 232 to RS 485 converter RS 485 to 1200m 4000ft For RS 485 installations the cable should be run in a daisy chain configuration i e converter position 1 position 2 p...

Page 12: ...unit every 90m By default MorphoAccess SIGMA Lite Series terminal is configured in Static mode Terminal Block Ethernet connection Extreme care must be taken while connecting Ethernet wire to the block...

Page 13: ...Data 0 Connect WIEGAND_OUT1 White wire Pin 16 to ACP Data 1 Connect WIEGAND_GND Black Red wire Pin 20 to ACP reader common 0vDC For 18 AWG the maximum cable distance is 500 ft 150m for 20 AWG the maxi...

Page 14: ...s not enabled Wiegand output must be configured before connecting to the ACP Note On installation the system administrator will be prompted to select either a pre existing Wiegand frame format or crea...

Page 15: ...gether Power supply Single Door Access Control SDAC wiring sample with Push Button Deadbolt Door strike Door contact Step four ACP or SDAC Power supply 19 RELAY_NO Yellow 21 RELAY_NC Orange 22 RELAY_C...

Page 16: ...an 1A damage to the device may occur If the deadbolt door strike load exceeds 1A an external relay must be used The internal relay is designed for 100 000 cycles If more cycles are needed an external...

Page 17: ...or database management terminal maintenance Step five administration Network connection methods Point to point Ethernet connection This method requires a static IP configuration except if DHCP server...

Page 18: ...ave the same network mask ex 255 255 255 0 if the 3 first bytes of IP address are the same for all terminals and PC Step five administration Configuration using MorphoBioToolbox Fill IP address and Ne...

Page 19: ...ded Web server enables easy configuration of the devices as well as user enrolment using a web browser on a Desktop PC Laptop Tablet or smart phone The connection to the embedded Webserver through LAN...

Page 20: ...MorphoBioToolBox for Windows Please note that this application has an embedded User Guide Help menu Terminal administration with MorphoBioToolBox application Step five administration North and South...

Page 21: ...ication version 8 0 3 or higher When Legacy Morpho mode enabled the terminal is compatible with MEMS version 7 3 1 or higher The limitations in Morpho Legacy mode are described in the following docume...

Page 22: ...ice use middle finger as 2nd choice use ring finger as alternative 2nd choice 3rd choice avoid little finger poor fingerprint avoid thumb best accuracy but ergonomically more difficult to use Fingerpr...

Page 23: ...n Finger Height Finger Angle IDEAL POSITION Incorrect Position Do not place the finger tip on the bottom of the sensor or in the middle of the sensor Correct Position Align centre of finger tip with s...

Page 24: ...24 Finger Inclination IDEAL POSITION Finger rotation IDEAL POSITION Incorrect Position Do not leave the finger in the air Do not bend finger upward or downward Correct Position Finger is parallel to s...

Page 25: ...Series Quick User Guide 2015_2000005700 V11 25 Waiting for card Step seven capture basics Access granted USB script finished Access denied USB script failed Place finger Move finger Fix blue Fix gree...

Page 26: ...SIGMA Lite Series basic MMI MorphoAccess SIGMA Lite Series Quick User Guide 2015_2000005700 V11 26 Step seven capture basics Waiting for card Access granted USB script finished Access denied USB scri...

Page 27: ...tored in the card at least the User ID and starts authentication process as required by terminal settings When defined by terminal settings the user is required to enter his PIN code once during enrol...

Page 28: ...IDEMIA DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED Contactless Card Position Warning MorphoAccess SIGMA Lite Series Quick User Guide 2015_2000005700 V11 28 Step seven capture basics...

Page 29: ...ovided by the user through a specific screen displayed during identification or authentication process The new screen contains 2 dedicated function keys One to specify an entry or a beginning of a tas...

Page 30: ...gularly and at least after significant changes in the database add remove or modification of user s records Date Time synchronization If you want to use the MorphoAccess SIGMA Lite Series terminal for...

Page 31: ...erminal operations Administration Guide This document describes the different functions available on the terminal and the procedures for configuring the terminal Parameters Guide This document contain...

Page 32: ...biometric terminals com To get your login and password please contact your sales representative Copyright 2020 IDEMIA All rights reserved www idemia com Reproduction in whole or in part in any form o...