Error Code List Chapter4. Cash & Check In Module
4-44
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I20C2
[Shutter]A wrong size is received
during USB CONTROL PIPE
communication.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I20C3
[Shutter]The size of USB bulk data
is 0 or not the multiple of 64.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I20CF
[Shutter]Fault of transmitting the
same seq of SP.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I2301
[Shutter] Low-speed moving
sensor fault.
1. Open the door at the Bundle side and
remove the residual media.
2. Check and remove the alien materials
in the Bundle low-speed wheel position
control (BDS14) sensor.
3. If no alien material exists, check
whether the sensor is polluted
4. Initialize the device.
I2302
[Shutter] Low-speed moving up
fault
1. Check whether the Bundle low-speed
moving path (BDM02) is running.
2. Reboot the system when the same
error occurs.
3. Replace the motor and cables when
the same error occurs after checking the
device.
I2303
[Shutter] Low-speed moving down
fault
1. Check whether the Bundle low-speed
moving path (BDM02) is running.
2. Reboot the system when the same
error occurs.
3. Replace the motor and cables when
the same error occurs after checking the
device.
I2304
[Shutter] Shutter sensor fault.
1. Check and remove the alien materials
in the Bundle Shutter Open (BDS11)
and Close(BDS12) sensors.
2. If no alien material exists, check
whether the sensor is polluted
I2305
[Shutter] Shutter Open fault.
1. Check the inside of the Bundle and
the Shutter.
2. Remove banknotes or the alien
materials in the Shutter.
3. Check whether the Shutter Open
successfully operates.
I2306
[Shutter] Shutter Close fault.
1. Check the inside of the Bundle and
the Shutter.
2. Remove banknotes or the alien
materials in the Shutter.
3. Check whether the Shutter Close
successfully operates.
I2307
[Shutter] Billpress sensor fault.
1. Check and remove the alien materials
in the Bundle Bill Press part (BDS15,
BDS16) sensors.
2. If no alien material exists, check