Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-319
Code
Problem Description
Troubleshooting
5AAA400
Status of BMU removal before
the operation during Retract
CSM.
1. Check Load/Removal of the upper
unit
5AAA600
Status of CSM open before the
operation during Retract CSM.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
5AAA700
Status of RJC removal before
the operation during Retract
CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
5AAA800
Status of BMD inter lock
detachment before the
operation during Retract CSM.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5AAA900
Status of BMD removal before
the operation during Retract
CSM.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5AAAA00
Status of BC open before the
operation during Retract CSM.
1. Open the upper unit
2. Check the lock lever in the BC
5AAE100
Received operation command
without Initial Info Set during
Retract CSM.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5AAE200
Status on not operation
receiption command during
Retract CSM.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5AAE300
Received operation command
without System Info Read
during Retract CSM.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5AAE400
Retract CSM transaction was
executed without Initializing
after power on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5AAE600
Error to received Retract CSM
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5AAEE00
RBU RS485 communication
sequence error during Retract
CSM.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5AAEF00
RBU RS485 connection line
error during Retract CSM.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization