Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-486
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5KAR700
Message timeout error of RBU
response during.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5KAR900
Stack ready message timeout
error when auto
recoveryduring Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5KARA01
BM notes revert message
timeout error when auto
recoveryduring Withdrawal
Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5KARB00
Remainder notes processed
message timeout error when
auto recoveryduring
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5KARJ00
Message timeout error under
the Stop Ready during
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5KAS800
Separate count is more than
Remain count when updating
notes count duringduring
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5KBH100
RC1 EEPROM read error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH200
RC2 EEPROM read error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH300
RC3 EEPROM read error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH400
RC4 EEPROM read error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH500
RC5 EEPROM read error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH600
RC1 EEPROM write error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH700
RC2 EEPROM write error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5KBH800
RC3 EEPROM write error
during Withdrawal Reject.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization