Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-517
Code
Problem Description
Troubleshooting
5QBS200
RBU connection MI error
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5QUS100
USB sequence number
duplicate error during Retract
CSM + TE.
1. Restart over AP-SP
5QUS300
USB command data length
error during Retract CSM + TE.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5RAE100
RBU connection sequence
error when Read Initial Info.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5RAE200
RBU connection sequence
error when Read Initial Info.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5RAE300
RBU connection sequence
error when Read Initial Info.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5RAE400
RBU connection sequence
error when Read Initial Info.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5RAE600
Error to received Read Initial
Info. during TE Button
Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5RAEE00
RBU connection sequence
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5RAEF00
RBU connection sequence
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5RAH500
Error to
NVRAM(128denominations)
Read/ Write when Read Initial
Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5RBH100
RC1 EEPROM read error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH200
RC2 EEPROM read error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH300
RC3 EEPROM read error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization