Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-504
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5Q6G200
BP notes out error during
Retract CSM + TE.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5Q6G300
BP separate position
movement error during Retract
CSM + TE.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5Q6G500
BP notes out position error
during Retract CSM + TE.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5Q6GD00
Failure to Lift-up during Retract
CSM + TE.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5Q6GE00
Failure to Lift-down during
Retract CSM + TE.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5Q6GF00
Failure to move gate roller to
home position during Retract
CSM + TE.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
5Q6M100
Stopper Init error during
Retract CSM + TE.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5Q6M300
Shutter close error during
Retract CSM + TE.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5Q6M400
Stopper down error during
Retract CSM + TE.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5Q6M500
Stopper up error during Retract
CSM + TE.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5Q6M600
Shutter Close error initializing
stopper during Retract CSM +
TE.
1. Open the upper unit
2. Check knob rotates softly in the
CSM(1)
3. Check inside of CSM
5Q6P100
PP withdrawal(stack) position
movement error during Retract
CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P200
PP deposit position movement
error during Retract CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)