Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-72
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5307Q00
Error occurred by the notes
disorder on the GS034 during
Deposit End.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5307W00
Error occurred by the notes
disorder on the GS802 during
Deposit End.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
530DR00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DS00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DT00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DU00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DV00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DW00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DX00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530DY00
Error of failure to synchronizing
recognition during Deposit
End .
1. Operate to initialize BRM(Recovery)
530F100
GM001 motor removal error
during Deposit End.
1. Open the upper unit
2. Check the Front Transport Path(4)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS804 status
530F200
GM002 motor removal error
during Deposit End.
1. Open the upper unit
2. Check the Rear Transport Path(8)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS007 status