Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-488
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5LAE100
Received operation command
without Initial Info Set during
Log Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAE200
Not be performed Received
Command during Log Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAE300
Received operation command
without System Info Read
during Log Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAE400
Log Read transaction was
executed without Initializing
after power on .
1. Operate to initialize BRM(Recovery)
5LAE600
Error to received Log Read.
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAEE00
RBU RS485 communication
sequence disorder during Log
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAEF00
RBU RS485 connection line
during Log Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5LAH500
Error to
NVRAM(128denominations)
Read/ Write during Log Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5LUS100
USB sequence number
duplicated error during Log
Read.
1. Restart over AP-SP
5LUS300
USB command data length
error during Log Read.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5NAE100
Received operation command
without Initial Info Set during
CST notes count Read.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5NAE200
Not be performed Received
Command during CST notes
count Read.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5NAE300
Received operation command
without System Info Read
during CST notes count Read.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5NAE400
CST notes count Read
transaction was executed
without Initializing after power
on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5NAE600
Error to received CST notes
count Read. during TE Button
Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization