Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-518
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5RBH400
RC4 EEPROM read error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH500
RC5 EEPROM read error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH600
RC1 EEPROM write error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH700
RC2 EEPROM write error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH800
RC3 EEPROM write error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBH900
RC4 EEPROM write error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBHA00
RC5 EEPROM write error
when Read Initial Info.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5RBHB00
RBU connection sequence
error when Read Initial Info.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5RBHC00
RBU connection sequence
error when Read Initial Info.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5RBHD00
RBU connection sequence
error when Read Initial Info.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5RBHE00
RBU connection sequence
error when Read Initial Info.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5RBHF00
RBU connection sequence
error when Read Initial Info.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5RBHG00
RBU connection sequence
error when Read Initial Info.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5RBS000
RBU communication timeout
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5RBS100
RBU connection sequence
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization