Error Code List Chapter4. Cash & Check In Module
4-34
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I1C06
[Initialize]FDS03, 04 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I1C07
[Initialize]BCS01 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I1C08
[Initialize]BCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I1C09
[Initialize]BCS01,BCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I1C0A
[Initialize]FDS15 Light Timeout
fault
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I1C0B
[Initialize]AAS06 is not reached
(Light JAM) fault when
separating media.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I1C0C
[Initialize]AAS05 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I1C0D
[Initialize]AAS03 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I1C0E
[Initialize]RCS01 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media