Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-142
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
546G400
BP separate control error
during Deposit Cancel .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
546G500
BP notes out error during
Deposit Cancel .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
546G800
Failure to revert notes during
Deposit Cancel (Separate
moter disorder).
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
546GA00
Failure to move
withdrawal(stack) position of
stack roller during Deposit
Cancel(GM605 disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
546GB00
Failure to move deposit(stack)
position of stack roller during
Deposit Cancel(GM605
disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
546GC00
Failure to control stack roller
during Deposit Cancel(GM605
disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
546GD00
Failure to Lift-up during
Deposit Cancel.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
546GE00
Failure to Lift-down during
Deposit Cancel.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
546GF00
Failure to move gate roller to
home position during Deposit
Cancel.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
546M100
Stopper Init error during
Deposit Cancel.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
546M300
Shutter close error during
Deposit Cancel.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
546M400
Stopper down error during
Deposit Cancel.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
546M500
Stopper up error during
Deposit Cancel.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM