Code
Problem Description
Troubleshooting
516GC00
Failure to control stack roller
during Deposit Ready Stack
roller (GM605 disorder).
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(3)
516GD00
Failure to Lift-up during
Deposit Ready
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
516GE00
Failure to Lift-down during
Deposit Ready
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
516GF00
Failure to move gate roller to
home position during Deposit
Ready.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
516P100
PP withdrawal(stack) position
movement error during Deposit
Ready .
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P200
PP deposit position movement
error during Deposit Ready.
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P300
PP separate position
movement error during Deposit
Ready.
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P400
PP lose return position
movement error during Deposit
Ready.
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P500
PP notes out error during
Deposit Ready .
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P600
PP notes alignment error
during Deposit Ready .
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P700
PP separate control(during
separating) error during
Deposit Ready .
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P800
PP stack control(during
stacking) error during Deposit
Ready .
1. Open the upper unit.
2. Check PP rotates softly using knob of
the CSM(1)
516P900
Error of reverting notes during
Deposit Ready .
1. Open the upper unit.
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the contamination of the
sensor in the CSM(2)
516PA00
PP ready stop error during
Deposit Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
516R100
CSM message timeout error
during operation ready in the
Deposit Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization