Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-327
Code
Problem Description
Troubleshooting
5B02P00
Error occurred by the notes
remained on the GS033 during
Retract TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B02Q00
Error occurred by the notes
remained on the GS034 during
Retract TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B02W00
Error occurred by the notes
remained on the GS802 during
Retract TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B05100
Error occurred by the
Transport Path on the GS801
during Retract TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B05200
Error occurred by the
Transport Path on the GS002
during Retract TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B05300
Error occurred by the
Transport Path on the GS003
during Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance