Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-21
Code
Problem Description
Troubleshooting
I160B
[Initialize]When media abnormally
access and are piled at the Reject
part, the residual media exist at
the Reject part (RJS08 Dark).
1. Remove the notes and alien materials
in the Reject output check sensor
(RJS08).
2. If no alien material exists, check
whether the sensor is polluted
I160C
[Initialize]Fault of performing a
undefined process flow from
Reject.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I16F1
[Initialize]Reject Task force shut
down.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1702
[Initialize]Fault of performing a
undefined process flow from
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1703
[Initialize]MICR force shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1704
[Initialize]Fault of calling a
undefined command from MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1705
[Initialize] MICR home
position(RCS02) Dark is not
detected while initializing MICR.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I1706
[Initialize] MICR home
position(RCS02) Dark is not
detected while initializing MICR.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I1707
[Initialize]MICR Moving Header
home position (RCS02) Light is
not detected while initializing
MICR.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. Check the cable connected to Moving
Header H.P(RCS02) sensor.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I1708
[Initialize]The first motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1709
[Initialize]The second motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I170A
[Initialize]The third motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I170B
[Initialize]Jam occurs at the Recog
entry sensor (RCS01) when
executing MICR.
1. Remove the internal media and alien
materials in the Recognition(5).
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.