Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-539
Code
Problem Description
Troubleshooting
5W8HG09
Error of country-code set up
during receiving BCU data
write command in the Initial
Info Set .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5W8HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Initial Info Set .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
5W8HG11
Error of no country code set up
during receiving BCU ready
command in the Initial Info
Set .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5W8HG12
BC spec differs from data write
command paramter during
Initial Info Set
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
5W8HG20
Error to initialize CIS during
receiving BCU ready command
in the Initial Info Set .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5W8HG21
Error of power on during
receiving BCU ready command
in the Initial Info Set .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5W8HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Initial Info
Set .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5W8HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the Initial
Info Set .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5W8HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Initial Info
Set .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance