Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-534
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5VAAD00
Status of UTC1 full before
excute System Info Read
command.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
5VAAE00
Status of UTC2 full before
excute System Info Read
command.
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
5VAAF00
Status of RC empty before
excute System Info Read
command.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
5VAE600
Error to received System Info
Read command. during TE
Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VAEE00
RBU RS485 communication
sequence disorder during
System Info Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VAEF00
RBU RS485 connection line
disorder during System Info
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VAH500
Error to
NVRAM(128denominations)
Read, Write duringSystem Info
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5VBH100
RC1 EEPROM read error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH200
RC2 EEPROM read error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH300
RC3 EEPROM read error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH400
RC4 EEPROM read error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH500
RC5 EEPROM read error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH600
RC1 EEPROM write error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH700
RC2 EEPROM write error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization