Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-8
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
512G100
Failure of return notes to RC2
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Put down the Stage after open the
recycle cassette door (B)
5.Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
512G200
Failure to move stack position
of RC2 PP during Deposit
Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Open the recycle cassette door (B)
5. Check cassette status to move stage
up and down
6. Check to demage lower edge of the
door´s right side(Key part) if you
don´t find any problem
512G400
Failure to upword moving of
PP during RC2 stack roller
retreat movement in the
Deposit Ready .
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Open the recycle cassette door (B)
5. Check cassette status to move stage
up and down
6. Check to demage lower edge of the
door´s right side(Key part) if you
don´t find any problem
512G500
Failure of RC2 stack roller
retreat during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Put down the Stage after open the
recycle cassette door (B)
5.Check the jam removal knob rotates
softly
512G600
Exceeds retry count limit of
detecting RC2 stack
roller´s falling back and
avoiding during Deposit
Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Put down the Stage after open the
recycle cassette door (B)
5.Check the jam removal knob rotates
softly
512G800
Failure to RC2 push pressure
movement during Deposit
Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Put down the Stage after open the
recycle cassette door (B)
5.Check the upper side of the recycle
cassette
512GA00
RC2 solenoid echo error
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the recycle cassette (B) .
4. Reload the recycle cassette (B) after
removing recycle cassette
5. Change the cassette when same
error occur