Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-57
Code
Problem Description
Troubleshooting
528HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Deposit
Count .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
528HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the Deposit
Count .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
528HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Deposit
Count .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
528HG36
Error of recognized mode
during receiving BCU mode
command in the Deposit
Count .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
528HG37
Error of transaction setting
during receiving BCU mode
command in the Deposit
Count .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
528R100
BC message timeout error
during operation ready in the
Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
528R200
BC message timeout error
during transaction operation in
the Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
528R300
BC message timeout error
during postprocessing of
Deposit Count Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
528R900
BC message timeout error
during Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
528S100
Receive abnormal MI from BC
during Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
528S200
Receive abnormal BCC from
BC during Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization