Error Code List Chapter4. Cash & Check In Module
4-122
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I4C06
[Deposit Count/Check]FDS03, 04
Light Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I4C07
[Deposit Count/Check]BCS01
Light Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I4C08
[Deposit Count/Check]BCS02
Light Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I4C09
[Deposit
Count/Check]BCS01,BCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I4C0A
[Deposit Count/Check]FDS15
Light Timeout fault
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I4C0B
[Deposit Count/Check]AAS06 is
not reached (Light JAM) fault
when separating media.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I4C0C
[Deposit Count/Check]AAS05
Light Timeout fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I4C0D
[Deposit Count/Check]AAS03
Light Timeout fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I4C0E
[Deposit Count/Check]RCS01
Light Timeout fault
1. Alignment(4) Open
2. Alignment(4) part residual media