background image

 

CDMA2000 1X EV-DO Wireless Data Terminal User Guide 

ZTE Corporation

  

http

:

//www

.

zte

.

com

.

cn 

 

 

 

 
 
 
 

CDMA2000 1X EV-DO 

Wireless Data Terminal 

User Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This User Guide is used for Wireless Data Terminal of AC2791. 

Summary of Contents for AC2791

Page 1: ...CDMA2000 1X EV DO Wireless Data Terminal User Guide ZTE Corporation http www zte com cn CDMA2000 1X EV DO Wireless Data Terminal User Guide This User Guide is used for Wireless Data Terminal of AC2791 ...

Page 2: ...ed No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without the prior written permission of ZTE Corporation ZTE Corporation reserves the right to make modifications on print errors or update specifications in this manual without prior notice ...

Page 3: ... Insert R UIM Card 2 3 2 Operation Guide of Data Cable 2 4 Install and Uninstall 3 4 1 System Requirements 3 4 2 Installation Guide 3 4 2 1 Install 3 4 2 2 Uninstall 3 5 Run the Application 4 6 Connect Disconnect 4 7 NetConnect Log 5 8 SMS 5 9 Phonebook 6 10 Settings 7 11 Help 9 12 Trouble shooting 10 13 FCC Regulations 12 14 4RF Exposure Information SAR 12 ...

Page 4: ... Do not directly pull out the terminal to avoid the damage of data terminal or the influence on the normal operation of operating system Do not forcefully plug pull the data terminal to avoid the damage of connector Do not use your data terminal near weak signal or high precision electronic devices Radio wave interference may cause misoperation of electronic devices or other problems Turn off your...

Page 5: ...ated by the arrow 3 Insert R UIM card as below figure 4 Push back R UIM card cover 3 2 Operation Guide of Data Cable Generally the Data Terminal could be directly connected with USB port You could also connect the Data Terminal with PC by using the accompanying data cable as shown in the following figure Connect Interface with Data Terminal and interface with PC s USB port If the power supply from...

Page 6: ...ot insert the Data Terminal before installation 4 2 1 Install 1 Please connect Data Terminal to PC through USB interface You could use the data cable to connect 2 The installation driver will automatically run Please install according to the installation wizard 3 The system will automatically find new hardware and install the driver Wait for a while Click Finish after the installation is completed...

Page 7: ...e function which indicate as below Connect Value Add SMS NetConnect NetConnect Log Phonebook Settings Help Status Bar 1X indication Unread message indication EV DO indication Inbox full indication Signal strength indication The more bars there are the stronger signals are No R UIM card inserted indication CDMA network unavailable R UIM card inserted indication Connection indication Roaming indicat...

Page 8: ...ew NetConnect Log NetConnect Log save the previous relevant information including Start at Duration and Transmit bytes which will help you know the status easily By switching among List Monthly and Statistic you could inquire the records every time by month or by time Note The relevant information contained in NetConnect Log are just for user s reference rather than the charging basis Delete Conne...

Page 9: ...so copy the messages from PC In box to the Data Terminal In box by selecting Copy Take Data Terminal In box as an example Reply Click to reply to the sender Forward Click to forward this message to other recipients Save Sender s Number Click to save the sender s number into Phonebook Delete Click to delete your selected records Clear Click to delete all the records in the inbox Copy Click to copy ...

Page 10: ...e or number Delete Click to delete your selected contact Delete All Click to delete all the contacts Send messages from the Phonebook Click to compose the text You could send the message to multiple recipients Copy Click to copy your selected contacts to other storage location Copy All Click to copy all contacts to other storage location Import the call history Click to import the Phonebook txt fo...

Page 11: ...ll please select Show 3 way call button during calling After the setting click Apply button to save the settings on the current interface Click Change Password button to set lock device The password is required when you start the application The setting has nothing to do with Default button Click the button Enable Pin PIN code is needed when the application is started The setting has nothing to do...

Page 12: ...st to the network system After the setting click Apply button to save the settings on the current interface Click Default button and then Apply button to restore the settings on the current interface to factory default Update Select Manual Upgrade or Auto Upgrade for the software 11 Help Click button to view the help file Click Help button to view the relevant help file click Online service to ent...

Page 13: ...sure it is in the CDMA network service area The antenna or RF component is damaged Replace relevant damaged parts Internet connection failure The Data Terminal is being connected It usually occurs when the Internet connection is immediately made after the call is dialed Reconnect Poor network signal View signal strength indication and check if the antenna is properly inserted The installation prog...

Page 14: ...unable to run normally if the terminal is pulled out and plugged in again when the application is being used under Win2000 SP4 operating system In this case the device in device manager will be marked with yellow exclamation mark and the system must be restarted to run normally The operating system needs installing Update Roll 1 patch for Win2K SP4 Please download the patch from the following web ...

Page 15: ...erienced radio TV technician for help 14 4RF Exposure Information SAR This device meets the government s requirements for exposure to radio waves This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government The exposure standard for wireless device employs a unit of measuremen...

Page 16: ... DO Wireless Data Terminal User Guide ZTE Corporation 13 http www zte com cn is on file with the FCC and can be found under the Display Grant section of www fcc gov oet ea fccid after searching on FCC ID Q78 AC2791V2 ...

Reviews: