background image

POTSwap 

– HSPA910PS Version

Product User Manual

Bulletin

JA16-GSM-UM

Revision

P05

Date

08 Sept 2015

Summary of Contents for POTSwap HSPA910PS

Page 1: ...POTSwap HSPA910PS Version Product User Manual Bulletin JA16 GSM UM Revision P05 Date 08 Sept 2015 ...

Page 2: ...e Operation 3 2 1 Placing Calls Manual Telephones Automated Dialers 3 2 2 Receiving Calls 3 2 3 Call Disconnect 3 2 4 Call Unconnected Busy 3 3 Data Operation 4 Configuration 7 10 5 External Interface 11 14 5 1 Front Panel Received Signal Strength Indicator LED Operational indicators POWER RED LED CELLULAR YELLOW LED STATUS GREEN LED PUSH BUTTONS PHONE FXS Connector 5 2 Rear Panel Power connectors...

Page 3: ...any injury loss or damage of any kind incurred by use of or reliance upon the information Connor Winfield disclaims any and all responsibility for the application of the devices characterized in this document and notes that the application of the device must comply with the safety standards of the applicable country and where applicable with the relevant wiring rules Connor Winfield reserves the r...

Page 4: ...all the functions of a wired telephone connection is fully compatible with all common modem standards and can be configured to emulate all international telephone line standards Wireless connectivity is provided by the Janus line of Plug In Terminus terminal modems which provide support for all current mobile network technologies with service available from numerous wireless carriers Configuration...

Page 5: ...ng GREEN STATUS LED a blinking CELLULAR LED and a steady signal strength indication on the Received Signal Strength LED stack 3 2 Voice Operation Voice operation requires a standard voice telephone device to be connected to the POTSwap 3 2 1 Placing calls When the connected telephone device is taken off hook the POTSwap will present an audio dial tone signal Dialing can proceed with up to 30 digit...

Page 6: ...a busy tone If this occurs the POTSwap will generate the busy tone locally for a period defined by the user configurable Busy Dwell Timeout parameter Following the busy tone the POTSwap will terminate the call by generating an Open Switching Interval see section 4 Configuration 3 3 Data Operation Future firmware feature Telephone modem equipment can be connected to the POTSwap for the purpose of c...

Page 7: ...o SLIC HE910 Power Up Mode Board has SiLabs Wire Line Modem E911 Voice Calling where system configuration permit allow Installer responsible for validation of service WireLine_Open 7 Speaker Level 4 Microphone Level 1 Echo Cancellation 25 Transport Mode 1 TTY Mode 900 Open Switching Interval 30000 Dialing Tone Timeout 4000 Dialing Digit Timeout 6000 Busy Dwell Timeout 0 Fixed Format Dialing 2 ADC ...

Page 8: ...MP Adr Len DO NOT USE Factory use only XMODEM Used for firmware upgrades REBOOT Entering REBOOT will restart the POTSwap similar to pressing the RESET button CONFIG Entering CONFIG will cause the configuration menu to be output Janus Remote Communications WireLine II Board POTSwap Configuration Microphone Level 4 0 7 Speaker Level 7 0 14 Echo Cancellation 1 0 1 Open Switching Interval 900 0 1200 m...

Page 9: ...ated busy tone AKA Kewlstart Dialing Tone Timeout1 30000 500 60000 Sets time limit for first dialing digit to be entered following going milliseconds off hook Exceeding the time limit will cause Open Switching Interval to be generated Dialing Digit Timeout1 6000 250 15000 Sets time limit for time between entering dialing digits milliseconds Exceeding the time limit will cause Open Switching Interv...

Page 10: ...eshold 8 default For REN 1 to REN 5 Voltage sensing threshold 10 Notes 1 Available on firmware versions 140725 and higher 2 12 on firmware versions 131011 and lower 3 Available on firmware versions 140207 and higher 4 Available on firmware 150908 and higher D DEFAULTS Command Entering the D command will change all of the settings back to the factory defaults These settings will not be saved unless...

Page 11: ... 3 Good 83 to 74 2 OK 93 to 84 1 Marginal 109 to 94 If no signal is detected the LED s on the stack alternately illuminate from bottom to top and back in a scanning manner LED Operational indicators LED LED COLOR INDICATION POWER Red Power status CELLULAR Yellow ellular radio status STATUS Green System status General status conditions can be inferred as follows Green and Yellow LED continuously ON...

Page 12: ...lizing PUSH BUTTONS Three push buttons are provided on the front panel of the POTSwap These can be operated with a small diameter object such as a paperclip There is tactile feedback that indicates when the push button has been operated Applying pressure to the push buttons beyond the point at which they actuate can damage the switch Currently the SELECT and MODE push buttons are not supported The...

Page 13: ...dustry standard 5 08 mm header that accepts a variety of terminal blocks including screw terminal spring clamp and crimp terminal type See Appendix A Compatible Terminal Block Connectors Circular Jack The circular DC jack has a 6 mm hole diameter and a 2 mm center pin It is designed to accept a 5 5 mm diameter plug with a 2 1 mm center hole and a 8 5 mm barrel length The center pin is the positive...

Page 14: ...PORT PINS PIN NUMBER FUNCTION NEMONIC DIRECTION 1 CARRIER DETECT CD OUTPUT 2 RECEIVED DATA RX OUTPUT 3 TANSMITTED DATA TX INPUT 4 DATA TERMINAL READY DTR INPUT 5 GROUND GND 6 DATA SET READY DSR OUTPUT 7 READY TO SEND RTS INPUT 8 CLEAR TO SEND CTS OUTPUT 9 RING INDICATOR RI OUTPUT Default communications protocol is 115200 baud 8 N 1 8 data bits no parity 1 stop bit with no handshaking SERIAL COMMUN...

Page 15: ...nstallation of an activated SIM card for operation The SIM card installation can be performed as follows Requirements POTSwap containing a Plug In Terminus with SIM card socket model HSPA910PS SIM card T10 TORX screwdriver Procedure 1 Disconnect all external cables from the POTSwap Remove the four TORX T10 screws from the rear enclosure panel the end that contains the POWER and SERIAL PORT connect...

Page 16: ...socket towards the outer edge of the POTSwap to unlock it as shown in the figure below The card holder is hinged on the outer edge lift it up and slide the SIM card into the holder flat end first chamfered end up The gold contacts on the SIM card will face down when the SIM card holder is closed Slide the card holder towards the center of the POTSwap to lock the card in place 4 Slide the board bac...

Page 17: ...oder and decoder Hybrid 2 wire to 4 wire conversion Testing DTMF encoding and decoding REN 5 at 100 ft 30m Modem Features 300bps to 56kbps Bell 103 and 212a ITU T V 21 V 22 V 22bis V 23 V 32 V 32bis V 34 V 90 and V 92 compatible Data Conversion Converts between modem analog PSTN data and IP packet data Voice Voice over cellular Data Routing Modem dialing information translation includes Fixed IP a...

Page 18: ...e of compatible connectors TYPE MANUFACTURER PART NO DESCRIPTION Screw Terminal TE Connectivity1 796634 2 vertical screw horizontal plug TE Connectivity 1986484 2 horizontal screw vertical plug Molex 395300002 vertical screw horizontal plug Molex 395332002 horizontal screw vertical plug Weidmuller 1943580000 vertical screw horizontal plug Spring Clamp Weidmuller 1013680000 orange Weidmuller 101343...

Page 19: ...ESCRIPTION HSPA910PS v1 0 HSPA UMTS EDGE GPRS GSM EVDO910PS v3 0 EV DO Verizon coming soon 10 Accessories The following accessories are available from Janus Remote Communications ACCESSORY DESCRIPTION JANUS STORE PART NUMBER POWER SUPPLY Wall transformer with circular DC connector 12V 2A MC 0004 ANTENNA Indoor 5 band GSM CDMA UMTS 3G ANT 0003 TERMINAL BLOCK Screw terminal block for the 5 08 mm pow...

Page 20: ...40 www janus rc com Revision History Revision Revision Date Note P00 11 23 13 Preliminary POTSwap User Manual Release P01 03 03 14 Overall Product Update Changes P02 05 08 14 Updated to GSM Version Only HSPA910PS P03 08 19 14 Updated Voice Operations and Configurations P04 08 11 15 Update to Enclosure and Dimensions P05 09 05 15 Operation Configuration Interfaces ...

Reviews: