manualshive.com logo in svg
background image

 

                           

             

 

1800 Series POS Bundle  

1800 POS Bundle Installation Guide 

Thank you for selecting UTC RETAIL’s innovative 1800 Series Point of Sale bundle solution! 

 

This guide is designed to help you efficiently assemble the 1800 Series POS Bundle System. 

 

 

 

 

© 2008 UTC RETAIL. All rights reserved. 

  11692014 Rev C 

 

 

 

 

Page 1 of 12 

 

 

 

Содержание ultimatouch 1800 series

Страница 1: ...n Guide Thank you for selecting UTC RETAIL s innovative 1800 Series Point of Sale bundle solution This guide is designed to help you efficiently assemble the 1800 Series POS Bundle System 2008 UTC RETAIL All rights reserved 11692014 Rev C Page 1 of 12 ...

Страница 2: ...his equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Safety Precautions DANGER High Voltage This unit contains high voltage There is a risk of electrical shock if the case is opened If service is required contact an authorized service agent or UTC RETAIL UTC WARNING CMOS Battery Damage...

Страница 3: ... 11692014 Rev C Page 3 of 12 Table of Contents 1800 Series POS Bundle System Installation Guide 2 Product Information 4 Un boxing the System 5 Installation 5 Powering On Your 1800 Series POS Bundle System 11 Troubleshooting Procedures 12 ...

Страница 4: ...gic device Cash drawer Barcode scanner POS receipt printer Keyboard Mouse Note The following optional items may or may not be present depending on the configuration purchased and may be shipped in a separate box Magnetic Stripe Reader MSR Payment Terminal Pin Pad device power supply cables Payment Terminal Signature Capture device power supply cables Rear Customer Display Inventory Scanner AC Powe...

Страница 5: ...cable package labeled APG cash drawer 320 Multipro cable kit Connect the end with the larger modular plug into the jack on the base of the cash drawer Figure 1 Bottom View of Drawer 2 Lay down the cash drawer and place the cable to the side 3 Connect the other end of the cash drawer cable to the POS printer drawer port labeled DK Figure 2 Bottom View of Drawer 2008 UTC RETAIL All rights reserved 1...

Страница 6: ...t the AC cable to the printer power supply and then to a wall outlet or the optional Power Conditioner Figure 3 Rear View of PC and Printer 6 Connect the mouse and keyboard cables to the PC The mouse port on the PC is green and the keyboard port is purple Figure 4 Rear View of PC and Top views of keyboard and mouse 2008 UTC RETAIL All rights reserved 11692014 Rev C Page 6 of 12 ...

Страница 7: ... and MSR Assembly 1 Connect the USB cable Insert the USB connector into the USB port at the side of the main unit 2 Position the MSR Align the MSR unit with the guide rails on the main unit and slide it into position making sure the entire USB cable is covered by the MSR housing 3 Insert and tighten screws Insert the two screws provided with the MSR unit and tighten to secure the MSR housing to th...

Страница 8: ...For instructions on the Signature Capture device cable connections refer to the install guide included with the terminal Plug the AC power adapter into a wall outlet or the optional Power Conditioner Figure 7 Rear View of PC Payment Terminal connection 2008 UTC RETAIL All rights reserved 11692014 Rev C Page 8 of 12 ...

Страница 9: ...el and then pull the panel straight up to expose the connecting cable Rear Panel Cover 2 Connect the cable Connect the cable between the Customer Display and the main unit Tuck the cable and connector into the opening 3 Snap the Customer Display into place Align the bottom of the Customer Display in the track Then slide the Customer Display straight down until it snaps into position 2008 UTC RETAI...

Страница 10: ... into a wall outlet or the optional Power Conditioner Figure 9 Rear View of PC Inventory Scanner connection 12 Connect a site provided network cable into the network jack on the back of the PC Figure 10 Rear View of PC Network cable connection 2008 UTC RETAIL All rights reserved 11692014 Rev C Page 10 of 12 ...

Страница 11: ...display 2 Turn on the ATX PC power by depressing the on off switch located on the lower front right hand side of the unit 3 To activate the printer turn on the printer rocker switch located on the front of the printer You have completed the installation of UTC RETAIL s 1800 Series Bundled Point of Sale System If you experience problems with any of the components of the 1800 Series Bundled POS Syst...

Страница 12: ...es not boot to Windows Push the ATX power button in the front of the logic unit located on the lower front right hand side of the unit A keyboard error message displays when you boot the 1800 Series POS unit Check to see if the keyboard cable is properly connected to the keyboard Make sure that the keyboard cable is connected to the keyboard port purple on the logic unit not to the mouse port gree...

Отзывы: