background image

 

 

 

 

 

 

 

 

 

PROGRAMMING TERMINAL

 

TP-10

 

Version 1.x   -  2007

 

                                                                  (TP-10-B) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This User Manual is property of SERRA SOLDADURA, S.A. 

SERRA  SOLDADURA,  S.A.  reserves  its  right  to  modify,  without prior notice, 
the  characteristics  of  the  TP-10  Programming  Terminal,  with  regards  to  the 
description in this Manual. 

Barcelona, March 2007 

 

Summary of Contents for TP-10

Page 1: ...10 B This User Manual is property of SERRA SOLDADURA S A SERRA SOLDADURA S A reserves its right to modify without prior notice the characteristics of the TP 10 Programming Terminal with regards to the description in this Manual Barcelona March 2007 ...

Page 2: ...TERMINAL PROG TP 10 User manual ...

Page 3: ...N 5 3 1 General 5 3 2 Wall mounting 5 3 3 Saving parameters on the TP 10 6 3 4 V24 connector signals 6 4 PROGRAMMING 7 4 1 Display 7 4 2 Keyboard 7 4 3 Utilities Menu 8 4 4 Automatic cursor positioning ACP 9 5 Messages 10 5 1 Introduction 10 5 2 Operation of the TP 10 in message mode 10 5 3 TP 10 Initialisation Stages 10 5 4 TP 10 Editor 11 5 5 PLC Display messages on the TP 10 11 5 6 PLC Receive ...

Page 4: ...TERMINAL PROG TP 10 User manual SERRA Soldadura S A ii ...

Page 5: ...le nature The TP 10 programming terminal is ergonomic robust reliable and simple to operate It has been designed to be able to handle the working conditions commonly found in industrial environments and is quick and easy to operate and can communicate with all SERRA controllers from the 7000 series onwards it allows you to modify and view data and will report any errors which arise Figure 1 1 Huma...

Page 6: ...Terminal complies with all requirements imposed by the European Directives referring to electromagnetic compatibility and also conforms to the EN 50081 2 generic Emission standards and EN 50082 2 generic Immunity standards which both apply to industrial environments Note The hardware of the TP 10 has been redesigned although the external housing remains the same To show that the new hardware versi...

Page 7: ...TP 10 PROG TERMINAL User manual SERRA Soldadura S A 3 2 TECHNICAL DATA 2 1 Dimensions The dimensions of the TP 10 Programming Terminal are shown below Figure 2 1 TP 10 dimensions in mm ...

Page 8: ...90 without condensation Maximum altitude 1000 m At higher altitudes lower temperature and humidity values apply 2 3 Weight TP 10 400 g TP 10 Wall Mount 100 g 2 4 Electrical characteristics Power supply 24 V DC 25 60 Consumption 6 VA 2 5 Keyboard Type Membrane 2 6 SERRA References and Codes TP 10 Programming Terminal 92000035 TP 10 Wall Mount 39927550 ...

Page 9: ... run through a cable sleeve The control data can be saved on the TP 10 Terminal This data can also be dumped to any other controller of the same series For the terminal to be able to function correctly with any SERRA controller from the 7000 series onwards the control data will need to be input via programming as is shown below Terminal functions also include a key press sound and dimming of the d...

Page 10: ...rs which can then be transferred to another controller requiring the same or similar parameters this saves time as the parameters do not need to be reprogrammed into the second controller The data is stored permanently in FLASH memory See the instruction manual for each specific controller for the precise method for using this function Versions fitted with the new hardware TP 10 are able to save S...

Page 11: ...1 F2 F3 F4 and F5 provide access to various menus of functions which are specific to each controller The arrow keys are used to change the cursor position within a Menu The and increase and decrease the cursor value by one unit The 0 9 number keys change the value of the numeric field of the cursor when this is allowed programming The C key sets the cursor value to zero The E key is used to valida...

Page 12: ... 8 9 C E F1 F2 F3 F4 F5 Figure 4 3 Keyboard Test Menu Once the key in question is pressed it will disappear from the screen and you will hear the buzzer sound The only key which cannot be tested using this menu is the F key To test this you will need to press the F combination and make sure that the programming unit Resets F2 CONFIGURATION Pressing F2 will take you to the Configuration Menu This h...

Page 13: ...d to between 1 and 15 minutes The and and right arrow and left arrow keys are used to increase or decrease each of these values Messages Activates or deactivates the TP 10 Messages mode To validate the data entered press E To exit the configuration menu without changing any of the data press F F5 F3 TP 10 Pressing F3 will exit the Utilities menu and the screen will be blank and dark for 2 seconds ...

Page 14: ...no specific messages to be displayed the TP 10 will display the message which the user has defined as the default message using the TP 10 Editor program The user can go to the parameter programming screen of the Serratrón at any time using the F F1 key combination The TP 10 will remain in this display mode until 10 minutes have passed during which the user does not press any key The user presses F...

Page 15: ...10 emits a beep No b1 The following characters will be flashing No b0 The following characters will not be flashing No nu Interprets the parameter as an integer without a sign occupying n positions Yes 1f The parameter is interpreted as a 5 figure number with 1 decimal place Yes c Interprets the parameter as an ASCII character Yes l1 Turns on the LCD light No l0 Turns off the LCD light No As we ca...

Page 16: ...quation could therefore be The copy block transfers the contents of counter C0 in the automation system to parameter 1 of the TP 10 The Msj24 block orders the TP 10 to display message 24 using the correct parameter 1 5 6 PLC Receive key presses from the TP 10 In message mode each key press on the TP 10 except some which are reserved will be sent to the Serratrón The PLC program can detect when a T...

Page 17: ...program executed on the TP 10 is constantly being improved and new versions are released as required Using the TP Editor and a Serratrón we can update the TP 10 firmware in a simple fashion To do this we will need the file containing the desired firmware and we download it into the TP 10 using the TP Editor ...