background image

3M

 Indoor Building Entrance 

Terminal (IBET) 4588VTP, 4588VSTP, 

4588VTPC and 4588VSTPC Series

with 3M

 Quick Connect System (QCS) 2811 Dry 

Flame-Retardant Block

Instructions

Underwriters Laboratories (UL 348X) Listed

May 2012
78-0013-6691-9-A

3

Содержание 4588VTP Series

Страница 1: ...ng Entrance Terminal IBET 4588VTP 4588VSTP 4588VTPC and 4588VSTPC Series with 3M Quick Connect System QCS 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories UL 348X Listed May 2012 78 0013 6691 9 A 3 ...

Страница 2: ...RetardantPluggable Module4005 DPM FRor3M 710Splicing SystemSDmodules b Splice chamber for the feeder cable with cable strain relief c Insulated 6 ground strap for the feeder cable d External bottom mounted three point ground bar and top mounted single point ground bar e Numbered standard 5 pin protector receptacle field f Binding post log and instruction label g The 3M Single Pair Test Probe and D...

Страница 3: ... ladder and where it will not project in a hazardous manner c Observe caution when exposing the terminal to chemicals in liquid or vapor form as they may damage the plastic components CAUTION Avoid locations near flammable materials ignitable gases dust moisture temperature extremes moving machinery electric light and power circuits and electrical equipment 2 2 Open the splicing chamber by looseni...

Страница 4: ...IBET Pull the gland and cable out of the IBET 2 3 6 Remove the sheath leaving at least 21 533 mm of free conductor length Identify and secure the cable groups ends Bond the cable shield according to your company s practice 3 7 Insert the gland s groove into the cable port Slide the PST over the gland and slowly unwind the core The PST core fits over either the small diameter of the 25 to 50 pair g...

Страница 5: ... openings in the cap making sure they are inserted all the way to the back of the cap 6 2 While holding the jumper wires in place close the cap and press to snap the latch firmly into place 6 3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways Cut jumper wires to appropriate length leaving at least 2 51 mm of slack 6 4...

Страница 6: ...ins to the distribution house wire 7 2 Insert protectors into the protector receptacle field according to your company s practice 7 3 To disconnect the distribution wire pull the protector out to the detents on the long pins to hold it in place This continues to protect from the feeder cable side 8 0 Protective Cover 4588VTPC and 4588VSTPC 8 1 With the cover closed the exposed hasp allows for lock...

Страница 7: ...ation Note Use this application when the required cable pair capacity exceeds the capacity of a single IBET 11 1 The design of the splice chamber and the grooved cable glands make it possible to stack the IBET vertically up to three of the same cable pair count and within the diameter limits in the chart in 3 1 11 2 Mounting the IBET a Mount the IBET bodies using the cable glands to position them ...

Страница 8: ...or a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s option to replace or repair the 3M product or refund the purchase price of the 3M product Except where pro...

Отзывы: