background image

Operating instruction

Maxi 3300MC

Coin box

Summary of Contents for Maxi 3300MC

Page 1: ...Operating instruction Maxi 3300MC Coin box ...

Page 2: ...or safe and proper use read the instructions for use and further product related documents carefully and keep it for later use For errors technical errors printing errors and incompleteness we assume no liability ...

Page 3: ...n in that execution brought by us in traffic corresponds to the standards specified down Diese Erklärung gilt für alle Geräte die nach den beiliegenden technischen Unterlagen welche Bestandteile dieser Erklärung sind hergestellt werden This explanation applies to all devices after the enclosed technical documents which are components of this explanation are manufactured Einschlägige EG Richtlinien...

Page 4: ...Holtkamp Electronics MAXI 3300MC english techn stand 09 2017 4019_11 2017 V09 2019 4 ...

Page 5: ...fications 13 10 General card 14 11 Programming 14 11 1 Method of programming 14 11 2 Time price menu 15 12 Configuration menu 17 12 1 Mechanical singel coin tester MMP 17 12 2 Electronic multi coin tester EMP 18 13 Basic settings 21 14 Enquiry card 22 15 Statistics 23 15 1 Delete of statistic values 23 15 2 Enquire of statistic values 23 16 Non programmable special equipment 24 16 1 Contactor 2 x ...

Page 6: ...al ATTENTION The installation must be performed by authorized personnel Therefore make sure that the installation is carried out by an electronics specialist Since this is a stationary device with main side fixed connecti on a circuit breaker must be installed on the instal lation side 4 Notes on cleaning and maintenance The device is mostly maintenance free By poor coin acceptan ce the coin runwa...

Page 7: ...nds after activate Serial number written on the type plate Commission Trader 6 General data Casing material Galvanised steel plate 1 5 mm Casing color Powder coated white RAL 9016 Design foil color yellow orange Custom design foil on request Dimensions H 255 mm x W 170 mm x T 135 mm Weight ca 4 0 kg Temperature range 0 TO 50 C Power supply 230 V or 24 V 50 60 Hz Switched power 6 3 A by cos phi 1 2...

Page 8: ...tion of the device 1 Casing 2 Coin tester 3 Coin slot 4 Coin reject button 5 Coin return 6 Coin bag 7 Lock 8 Coin remove 9 Card slot for general card 10 Front plate 11 LED display 12 Design foil Standard Ausführung Special equipment The coin reject button can be used also as door opener 1 2 3 4 5 6 7 9 10 11 12 8 ...

Page 9: ... button 3 Connection for time hold cleaning button or door opener 4 Connection for delete button 5 Jumper LöFrei 6 Connection for general equiry card 7 Connection for bypass swithcn 8a Additional relay for 110 disconnection 8b Main relay 8c Run out relay 9 Electrical connection 10 Fuse PCB special equipment a b c N L L Lü 1 2 3 4 5 6 7 8 9 10 Circuit board MC Gen2 V100 230V ...

Page 10: ...eattachedelectricconsu mer It should be used an cross section from 1 5 mm at the minimum 8 2 Mounting notes This device may only be mounted on a suitable surface The device must be sufficiently secured take into consi derationtheweightoftheinsertedcoins Thereare3holesin the back of the casing to accomplish the mounting process Screws and dowels are included by delivery The device must be mounted h...

Page 11: ...ut by authorized and qualified personnel The electrical connection has to be carried out by the local VDE regulations With a permanent connection an all pole mains se parator with at least 3 mm contact gap must be used Before starting the electric the corresponding circuit must be dis connected Shut down the mains input by activating the sepa rator switch remove the fuse or release the main safety...

Page 12: ... 2 27 A11 VDE 0700 part 27 As of May 2003 are all MAXI devices automati cally made according to the regulations above with re commended shutdown EN60335 2 27 The PCB of MAXI is provided with a 110 disconnection It me ans that an emergency stop timer is controlled by a third relay on the PCB It guarantees the switching off of the sun bed if the main relay is not switching off once after the expired...

Page 13: ...3 digitys Programming with general card Price setting coin value Minimum insert Short time sale Money counter Operating hour counter Service hour counter Customer counter Token counter only by EMP Contactor Time stop cleaning button door opener Remote start General card owner once per commission Statistic enquiry card owner personnel Customer design foil on request Standard Special equipment Produ...

Page 14: ...alues which should be adjusted will be increased By pressing MINUS button the values which should be adjusted will be decreased 11 Programming 11 1 Method of programming 1 Take off the coin remove 2 Push in the general card in the card slot with the buttons upwards 3 Press PROG button at once You are now in the program ming mode Time Price menu 4 Leave through the programming positions with NEXT b...

Page 15: ...asons after finish pre run time in tanning sector Should a connected device be operated without delay and activating the remote start the jumper FS must be activated on 0 The remote start has to be carried out basically poten tial free to the external tester on the sun bed Maximum time The maximum time is the limit of the main time It is adjustable in minute steps to max 9 hours 59 minutes beneath...

Page 16: ...nimum insert is activated Short time sale The short time sale offers the possibility for activation of partial main time sale per coin insert The payment of partial main time takes place by inserting the first coin The display shows 0 short time sale is deactivated The display shows 1 short time sale is activated The program of MAXI ensures that will be activated the minimum insert or the short ti...

Page 17: ... 5 Programming position current value current value E6 is the channel value for the token This will be adjusted facto ry made on 3 5 EUR Sfr Nkr Dkr Should be changed this value act as follows stuck jumper LöFrei on the PCB adjusted factory made press the PROG button twice dial the position which should be changed with the NEXT button adjusted the desired value with PLUS or MINUS button Example Ch...

Page 18: ...tester MMP in the MAXI 1 insert the coin 2 the coin will be assigned to the channel in the MMP 3 the channel of the MMP will be assigned to the channel of the MAXI 4 the channel of the MAXI will be assigned to the programmed value factory made or individual EUR 0 50 1 E1 z B 0 50 EUR factory m EUR 1 00 2 E2 z B 1 00 EUR factory m EUR 2 00 3 E3 z B 2 00 EUR factory m EUR 0 20 4 E4 z B 0 20 EUR fact...

Page 19: ...ktion no EURO yes 2 0 EURO narrow yes 1 2 3 4 5 6 7 8 Token Standard no 0 2 EURO wide no 0 2 EURO middle no Token Contours no 0 5 EURO middle yes 1 0 EURO wide yes 1 0 EURO middle yes Aktivation coin acceptance yes In the basic adjustment of the EMP the channels for 0 2 Euro and the tokens are closed You can enable and disable individual coin types with the help of certain DIP switch combinations ...

Page 20: ...t the cleaning staff was called upon to clean the sun bed After cleaning the staff ac tivates the cleaning button the indication is finished An LS The display shows IP the door opener short time impul se is activated special equipment There is a special function forwashing machine dooropening Ifthemaintimeisrunning out the washing machine is switched strain free and by any machines you can not ope...

Page 21: ...ain time presentation 0 0 9h59min 1 999min B1 Minimum insert 0 B2 Short time sale 0 H1 Start barrier 1 U1 Fan pre run 0 1 Yes 2 No 13 Basic settings The factory programming of your MAXI is presented on this page To give you a reminder there is a free field to the entry for your personal programming behind each programming value Configuration menu PROG button 2x Channel value by electronical coin t...

Page 22: ...ning button door opener short time impulse special equipment 0 LS Delete locking time 0 min 14 Enquiry card With the enquiry card the statistic values can be only prompted The enquiry card is not include the delivery from standard and must be ordered extra when desired By pressing the NEXT button the statistic menu is call up and the first statistic position is indica ted Another pressing of NEXT ...

Page 23: ...y card Select the position which should be enquired with NEXT button Money counter 10000 1000 and 100 position Money counter 10 1 and decimal position Counts all coins which have been inserted of the EMP channels 1 5 For reading out the values the both enquiry values must be men tal placed one behind the other and one obtains the exact coun ter stand Token impulse counter 10000 1000 and 100 positi...

Page 24: ...side on the underneath of the casing 16 6 Connectivity for delete button The connectivity for the cancel button offers the possibility to de lete the pre run and main time over an external button The run out time can t be deleted Is the delete signal durably the display show 3 bars If you have ordered your MAXI with connection possibility for cancel button inside of the back side of the casing an ...

Page 25: ...ains hanging in the coin tester foreign objects in the coin tester mechanic remove foreign objects coin tester defective send coin tester for adjustment The coin tester takes on every coin but no time is loaded The price not paid completely paid price completely wrongly programming correct the programming of the value and the basic programming Connectors is loose Plug in the connectors correctly A...

Page 26: ...tes 10 K Key switch for free use 24 L Legal information 6 M Main time 15 Main time presentation 16 Malfunctions 25 Maximum time 15 Mechanical singel coin tester MMP 17 Method of programming 14 Minimum insert 16 Monting instructions 10 Mounting notes 10 N Non programmable special equipment 24 O Operating hour counter 23 Operating the first time 12 P Potential free relay contact 24 Power depending t...

Page 27: ...Holtkamp Electronics MAXI 3300MC english techn stand 09 2017 4019_11 2017 V09 2019 27 ...

Page 28: ...de Technical Stand 09 2019 We reserve the right to technical changes in the production and technical developments For technical information during our business hours Monday Thursday 8 00 a m 16 00 p m and Friday 8 00 a m 13 00 p m choose 49 541 97120 0 or visit our homepage www holtkamp de ...