Common measurement settings
R&S
®
FSVA3000/ R&S
®
FSV3000
449
User Manual 1178.8520.02 ─ 08
span > 0: span
min
/2 ≤ f
center
≤ f
max
– span
min
/2
zero span: 0 Hz ≤ f
center
≤ f
max
f
max
and span
min
depend on the instrument and are specified in the data sheet.
Remote command:
Span
Defines the frequency span. The center frequency is kept constant. The following
range is allowed:
span = 0: 0 Hz
span >0:
span
min
≤ f
span
≤ f
max
f
max
and span
min
are specified in the data sheet.
Remote command:
Start / Stop
Defines the start and stop frequencies.
The following range of values is allowed:
f
min
≤
f
start
≤ f
max
– span
min
f
min
+ span
min
≤
f
stop
≤ f
max
f
min
, f
max
and span
min
are specified in the data sheet.
Remote command:
Full Span
Sets the span to the full frequency range of the R&S
FSV/A specified in the data sheet.
This setting is useful for overview measurements.
Remote command:
Zero Span
Sets the span to 0 Hz (zero span). The x-axis becomes the time axis with the grid lines
corresponding to 1/10 of the current sweep time ("SWT").
Remote command:
FREQ:SPAN 0Hz
, see
Last Span
Sets the span to the previous value. With this function you can switch between an
overview measurement and a detailed measurement quickly.
Remote command: