Measurements and results
R&S
®
FSVA3000/ R&S
®
FSV3000
283
User Manual 1178.8520.02 ─ 08
File contents
Explanation
File data section
0;9000;150000;1000;79500;-25.006643295288086;-
12.006643295288086;PASS;
0;9000;150000;1000;101022.11126961483;-47.075
111389160156;-34.075111389160156;PASS;
0;9000;150000;1000;58380.171184022824;-47.079
341888427734;-34.079341888427734;PASS;
Measured peak values:
<range number>;
<start frequency>;
<stop frequency>;
<resolution bandwidth of range>;
<frequency of peak>;
<absolute power in dBm of peak>;
<distance to the limit line in dB>; (positive value
means above the limit)
<limit fail (pass = 0, fail =1)>;
5.8
Statistical measurements (APD, CCDF)
To measure the amplitude distribution, the R&S
FSV/A has simple measurement func-
tions to determine both the Amplitude Probability Distribution (APD) and the Comple-
mentary Cumulative Distribution Function (CCDF). Only one of the signal statistic func-
tions can be switched on at a time.
......................................................................................283
...............................................................................................284
......................................................................................... 284
APD and CCDF basics - gated triggering
............................................................. 286
............................................................................... 288
How to perform an APD or CCDF measurement
..................................................294
Optimizing and troubleshooting the measurement
................................................298
5.8.1
About the measurements
The probability of amplitude values can be measured with the Amplitude Probability
Distribution function (APD). During a selectable measurement time all occurring ampli-
tude values are assigned to an amplitude range. The number of amplitude values in
the individual ranges is counted and the result is displayed as a histogram.
Alternatively, the Complementary Cumulative Distribution Function (CCDF) can be dis-
played. It shows the probability that the mean signal power amplitude will be exceeded
in percent.
Only one of the signal statistic functions can be switched on at a time. When a statistic
function is switched on, the R&S
FSV/A is set into zero span mode automatically. The
R&S
FSV/A measures the statistics of the signal applied to the RF input with the
defined analysis bandwidth. To avoid affecting the peak amplitudes the video band-
width is automatically set to 10 times the analysis bandwidth. The sample detector is
used for detecting the video voltage.
Statistical measurements (APD, CCDF)