Performing a spurious measurement
....................................................................974
Retrieving and saving settings and results
............................................................974
Programming example: spurious emissions measurement
.................................. 974
12.5.7.1
Initializing the measurement
Note that with the R&S
FSV/A, the spurious measurement must be initialized before
you can start configuring the sweep list or list evaluation.
INITiate<n>:SPURious
This command initiates a Spurious Emission measurement.
Suffix:
<n>
.
12.5.7.2
Configuring a sweep list
The following commands configure the sweep list for spurious emission measure-
ments.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
Useful commands for configuring the sweep described elsewhere:
●
Remote commands exclusive to spurious measurements:
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution
............................................................ 964
[SENSe:]LIST:RANGe<ri>:BANDwidth:VIDeo
................................................................... 964
....................................................................................964
..................................................................................965
................................................................................... 965
[SENSe:]LIST:RANGe<ri>:DETector
.................................................................................965
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STARt
................................................................ 966
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STOP
.................................................................966
[SENSe:]LIST:RANGe<ri>:FILTer:TYPE
............................................................................967
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation
................................................................... 968
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation:AUTO
......................................................... 968
[SENSe:]LIST:RANGe<ri>:INPut:GAIN:STATe
...................................................................968
[SENSe:]LIST:RANGe<ri>:INPut:GAIN[:VALue]
.................................................................969
[SENSe:]LIST:RANGe<ri>:LIMit:STARt
.............................................................................969
[SENSe:]LIST:RANGe<ri>:LIMit:STATe
.............................................................................969
[SENSe:]LIST:RANGe<ri>:LIMit:STOP
............................................................................. 969
[SENSe:]LIST:RANGe<ri>:POINts[:VALue]
....................................................................... 970
................................................................................... 970
Configuring and performing measurements