Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1290
User Manual 1178.8520.02 ─ 08
12.10
Configuring the R&S
FSV/A
The remote commands required to set up the R&S
FSV/A are described here.
Configuring the reference frequency
...................................................................1290
........................................................................................1293
....................................................................................1297
Compensating for frequency response using touchstone files (R&S
............................................................................1319
Remote commands for language settings
...........................................................1326
Configuring the network and remote control
....................................................... 1327
.............................................................................................. 1331
Checking the system configuration
..................................................................... 1337
Signal generator control commands
................................................................... 1346
....................................................................................... 1347
Remote commands for synchronizing parameters
..............................................1349
Configuring the application starter
...................................................................... 1366
12.10.1
Configuring the reference frequency
.......................................................................................1290
........................................................................................... 1291
........................................................................................... 1291
[SENSe:]ROSCillator:EXTernal:FALLback
...................................................................... 1291
SOURce<si>:EXTernal<ext>:ROSCillator:EXTernal:FREQuency
.......................................1291
...................................................................................... 1292
[SENSe:]ROSCillator:SOURce:EAUTo?
......................................................................... 1292
.......................................................................................1293
[SENSe:]ROSCillator:LBWidth
<Bandwidth>
Defines the loop bandwidth, that is, the speed of internal synchronization with the refer-
ence frequency. The setting requires a compromise between performance and increas-
ing phase noise.
For a variable external reference frequency with a narrow tuning range (+/- 0.5 ppm),
the loop bandwidth is fixed to 0.1 Hz and cannot be changed.
Parameters:
<Bandwidth>
0.1 Hz | 1 Hz | 3 Hz | 10 Hz | 30 Hz | 100 Hz | 300 Hz
The possible values depend on the reference source and tuning
range (see
Default unit: Hz
Example:
ROSC:LBW 3
Manual operation:
See
Configuring the R&S
FSV/A