Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1052
User Manual 1178.8520.02 ─ 08
<LimitLow>4.860</LimitLow>
<LimitHigh>5.940</LimitHigh>
<MeasValue>5.405</MeasValue>
<State>PASSED</State>
<Version>1.0.0</Version>
</SequenceStep>
<SequenceStep>
<Name>SYNTH_5V4_YIG</Name>
<LimitLow>4.860</LimitLow>
<LimitHigh>5.940</LimitHigh>
<MeasValue>5.438</MeasValue>
<State>PASSED</State>
<Version>1.0.0</Version>
</SequenceStep>
<SequenceStep>
<Name>SYNTH_M5V</Name>
<LimitLow>-5.500</LimitLow>
<LimitHigh>-4.500</LimitHigh>
<MeasValue>-4.948</MeasValue>
<State>PASSED</State>
<Version>1.0.0</Version>
</SequenceStep>
<SequenceStep>
<Name>SYNTH_REF5V</Name>
<LimitLow>4.500</LimitLow>
<LimitHigh>5.500</LimitHigh>
<MeasValue>5.031</MeasValue>
<State>PASSED</State>
<Version>1.0.0</Version>
</SequenceStep>
</SequenceCategory>
<SequenceCategory>
<Name>Supply Voltage</Name>
<Description>test description</Description>
<State>PASSED</State>
<Version>1.0.0</Version>
<Type>Diagnose</Type>
<SequenceStep>
<Name>SUPPLY_12V</Name>
<LimitLow>10.800</LimitLow>
<LimitHigh>13.200</LimitHigh>
<MeasValue>11.909</MeasValue>
<State>PASSED</State>
<Version>1.0.0</Version>
</SequenceStep>
<SequenceStep>
<Name>SUPPLY_3V3D</Name>
<LimitLow>2.970</LimitLow>
<LimitHigh>3.630</LimitHigh>
<MeasValue>3.318</MeasValue>
Setting basic measurement parameters