![Rohde & Schwarz FSV3000 User Manual Download Page 878](http://html.mh-extra.com/html/rohde-and-schwarz/fsv3000/fsv3000_user-manual_1477843878.webp)
Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
878
User Manual 1178.8520.02 ─ 08
CALCulate<n>:LIMit<li>:ACPower:ACHannel[:RELative]:STATe
<State>[, <State>]
This command turns the relative limit check for the adjacent channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe]
.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
Relative limit check for lower adjacent channel
*RST:
0
<State>
ON | OFF | 1 | 0
Relative limit check for upper adjacent channel
*RST:
0
Manual operation:
See
See
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>:ABSolute
<LowerLimit>[,
<UpperLimit>]
This command defines the absolute limit of the alternate channels.
If you have defined an absolute limit as well as a relative limit, the R&S
FSV/A uses the
lower value for the limit check.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
<ch>
1..n
Alternate channel number
Parameters:
<LowerLimit>
The limit of the lower adjacent channel.
Range:
-200 dBm to 200 dBm
*RST:
-200 dBm
Default unit: dBm
<UpperLimit>
The limit of the upper adjacent channel.
Range:
-200 dBm to 200 dBm
*RST:
-200 dBm
Default unit: dBm
Manual operation:
See
See
Configuring and performing measurements