Measurements and results
R&S
®
FSVA3000/ R&S
®
FSV3000
133
User Manual 1178.8520.02 ─ 08
5
Measurements and results
Access
: "Overview" > "Select Measurement"
Or
: [MEAS]
In the Spectrum application, the R&S
FSV/A provides a variety of different measure-
ment functions.
●
Basic measurements
- measure the spectrum of your signal or watch your signal
in time domain
●
Power measurements
- calculate the powers involved in modulated carrier signals
●
Emission measurements
- detect unwanted signal emission
●
Statistic measurements
- evaluate the spectral distribution of the signal
●
Special measurements
- provide characteristic values of the signal
●
EMI measurements
- detect electromagnetic interference in the signal
The individual functions are described in detail in the following chapters.
The measurement function determines which settings, functions and evaluation meth-
ods are available in the R&S
FSV/A. The various measurement functions are descri-
bed in detail here.
When you select a measurement function, the measurement is started with its default
settings immediately and the corresponding measurement configuration menu is dis-
played. The measurement configuration menu can be displayed at any time by press-
ing the [MEAS CONFIG] key.
The easiest way to configure measurements is using the configuration "Overview", see
Chapter 6.1, "Configuration overview"
In addition to the measurement-specific parameters, the general parameters can be
configured as usual, see
Chapter 6, "Common measurement settings"
Many measurement functions provide special result displays or evaluation methods;
however, in most cases the general evaluation methods are also available, see
ter 7, "Common analysis and display functions"
After a preset, and when all other functions are switched off ("All Functions Off" in the
"Select Measurement" dialog) the R&S
FSV/A performs a basic frequency sweep.
The remote commands required to retrieve measurement results are described in
Chapter 12.8.2.4, "Retrieving trace results"
..............................................................................................134
.............................................................................................135
Channel power and adjacent-channel power (ACLR) measurement
............................................................................ 214
Occupied bandwidth measurement (OBW)
...........................................................218
Spectrum emission mask (SEM) measurement
....................................................225
Spurious emissions measurement
........................................................................270
Statistical measurements (APD, CCDF)
............................................................... 283
........................................................................298
Harmonic distortion measurement
........................................................................ 304